What is armorlite used for?

What is armorlite used for?

Southwire’s Armorlite® type MC cable is used for branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.

What size is 12 2 MC cable?

12 gauge 2 conductors w/ ground copper MC Cable. Sold by the spool. 250 ft….Ampere Rating THHN: 20.

Cable Type MC
# of Conductors 2 Conductors w/ Ground
Conductor Material Bare Copper
Stranded or Solid Solid
O.D. (Inches) 0.477

Can MC cable be used outdoors?

These cables can be installed either indoors or outdoors and in exposed and concealed locations. They can be direct buried, where identified for such use. Type MC cable with a nonmetallic jacket can also be used in a wet location.

How much does a roll of 12 2 MC weigh?

Specifications for this item

Brand Name Southwire
Item Weight 5.20 pounds
Length 13.65 inches
Load Capacity 1 pounds
Material Aluminum

What is the difference between 12 2 and 12 3 wire?

The designation 12/2 indicates AWG 12 wire with two conductors (AC hot and AC neutral), 12/3 indicates AWG 12 wire with three conductors (two AC hot and AC neutral). Both designations also typically include a smaller bare copper earth ground conductor. AWG 12/2 is used for a single breaker 120V 20A max circuits.

What is a 12 2 wire?

“12-2” means 12 gauge, two insulated current carrying wires, plus a bare ground. 12-2 wire usually has a black, white and bare ground wire. Sometimes the white is red instead for 220V circuits without neutral. In the latter case, the sheath is usually red too.

How far can you run 12 2 MC cable?

12-Gauge/2-Gauge Solid CU MC (Metal Clad) Armorlite Cable. Covers 250 ft. (71¢ /ft.)

Can you use MC in damp locations?

Options for wet and damp location cable Type AC cable is approved by the NEC for use only in dry locations. In order to comply with the NEC for use in wet locations, interlocked Type MC Cable must have a corrosion resistant jacket and wet location rated conductors.

Is it OK to run MC cable exposed?

Section 330.15 states: Exposed runs of cable, except as provided in 300.11(A), shall closely follow the surface of the building finish or running boards. Exposed runs shall also be permitted to be installed on the underside of joists where supported at each joist and located so as not to be subject to physical damage.

How much does 1000ft of 12 2 MC weigh?

Weight per 1000 ft: 160 lbs.

Can you use 12-2 wire to run 220?

Perhaps you mean 12/2 wire to be used with 220 Volts power supply.so,yes you can. size of conducting wire is independent of the voltage with which it has to be used. Higher the voltage, more is the thickness of the insulation.

What is Armorlite type MC Cable?

Southwire Armorlite Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90 degree C dry available in sizes 14 AWG through 2 AWG and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly.

Where can Southwire Armorlite be used?

Southwire Armorlite® Type AC Cable is suitable for use as follows: Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings. Dry locations only. Environmental air-handling spaces per NEC 300.22 (C).

What is an interlocked armor Assembly?

An armor assembly (combination of the interlocked armor & bonding strip) that is recognized as an equipment grounding/bonding conductor per NEC 250.118 (8). Reduces installation costs up to 50% over pipe and wire.

What is aluminium interlocking armor used for?

Aluminum interlocking armor is applied over the assembly. Branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings Under raised floors for information technology equipment conductors and cables per NEC 645.5 (D) and 645.5 (D) (2)